The RUNET II, ES-9810/L & ES-9810/H1 devices, are intelligent, rugged multi channel, MIL-STD-1760 adapters. Its small size and ability to interface through Ethernet interfaces make it a complete solution for developing, testing and performing system simulation of the MIL-STD-1760 bus, both in the lab and in rugged environments.
The ES-9810 shares its API with the entire Px family so that applications currently running on PCI, PCIe, ExCARD or PCMCIA boards will run without change on this device.
Multiple units can operate on the same network, by programming each one with a unique IP address, and can be accessed from any computer on the network.
Multi Function
Each channel of the ES-9810/L1 operates simultaneously as a Bus Controller and/or multiple (up to 32) Remote Terminals, or as a Triggerable Bus Monitor. The card supports error injection and detection. The adapter’s small size and compatibility with any computer using Ethernet, makes it the perfect solution for performing system simulation of the MIL-STD-1760 bus, in the lab and in rugged environments.
Single Function
Each channel of the ES-9810/H1 operates either as a Bus Controller, Remote Terminal, or Bus Monitor.
The ES-9810/L1 and ES-9810/H1 adapters are supplied with C drivers, including source code and may be used with Exalt, Excalibur’s Analysis and Laboratory Tools, a Windows monitoring application.
Ordering Information:
Part Number |
Description |
ES-9810/L1xxx |
Single channel MIL-STD-1760 multi function interface box |
ES-9810/H1xxx |
Single channel MIL-STD-1760 single function interface box |
Mating Connectors & Cable Assemblies are NOT INCLUDED
Note: "x” specifies a protocol.
Additional options:
A* - ARINC-429 |
A0 = Five programmable channels
|
C* - ARINC-708 |
Two programmable channels
C1 = 1 transmit 1 receive C2 = 2 receive channels
|
D* - H009 |
One H009 channel
|
H* - MIL-STD-1760 |
One single function channel
H1 = transformer coupled H2 = direct coupled
|
I* - Discrete I/O |
I0 = programmable 10 D I/O, TTL/Avionics 0-32V DC
|
J* - RS232/422/485 |
Two channels, Baud rate RS-232 up to 3 Mbps, RS-422/485 up to 4 Mbps
J1 = 2 channel RS-232 J2 = RS-232 / RS-485 J3 = RS-232 / RS-422
J4 = 2 channel RS-485 J5 = RS-485 / RS-422 J6 = 2 channel RS-422
|
M* - MIL-STD-1760 |
Monitor only (transmit disabled)
M1 = transformer coupled M2 = direct coupled
|
N* - ARINC-717 |
Two channels Rx/Tx, HBP and BPRZ signals
N1 = HBP N2 = BPRZ
|
P* - ADDA |
up to 10 single ended, or 5 differential, digital-to-analog (DAC) output channels, as well as 5 single ended or 5 differential analog-to-digital (ADC) input channels.
P1 = DAC outputs only (10 Single Ended or 5 Differential)
P2 = ADC inputs only (5 Single Ended or 5 Differential)
P3 = Combined DAC and ADC
(4 Single Ended or 2 Differential DAC outputs and 3 Single Ended or 3 Differential ADC inputs)
|
R* - MMSI |
Five channels meets requirements of AS5643, 10Mbps 1553 Protocol/RS-485 Transceivers
R5 = 5 EBR-1553 hub ports and 1 cBM port
|
S* - ARINC-825
(canbus)
|
Five channels
S5 = 5 ARINC-825 channels
|
T* - MIL-STD-1553 |
One single function channel
T1 = transformer coupled T2 = direct coupled
|
V* - MIL-STD-1553 |
Monitor only (transmit disabled)
V1 = transformer coupled V2 = direct coupled
|
-S = Ground return isolated from shield -IP = Ingress Protection